商品详细Dojindo/DPPH抗氧化剂检测试剂盒/500/D678
Dojindo/DPPH抗氧化剂检测试剂盒/500/D678
Dojindo/DPPH抗氧化剂检测试剂盒/500/D678
商品编号: D678
品牌: 同仁
市场价: ¥3800.00
美元价: 2280.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
DescriptionQ & AManualS.D.S

Product DescriptionChanges in antioxidant capacity of the body are involved in the development of various diseases and health problems. As a result, this increases expectations for foods with antioxidant activity (antioxidant foods). Kochi University’s Shimamura et al. have developed a method using DPPH (2,2-Diphenyl-1-picrylhydrazyl) for evaluating antioxidant activity with little difference between measurement facilities1). This product uses a method including a microplate based on the report of Shimamura et al. By manualizing the DPPH measurement method and producing a kit of stable and constant quality, we were able to reduce data variability and complexity of reagent preparation, which has experienced issues until now.1) T. Shimamura et al., Anal. Sci., 2014, 30, 717 – 721


Simple ProcedureDPPH and Trolox are unstable in solution. Please prepare immediately before using.DPPH content needs to be checked by measuring absorbance.Reagents necessary for measurement are inlcuded and subdivided. Begin experiments immediately with simple preparation before measurement.(Please use sonication to dissolve the DPPH Reagent.)


Measuring methodAfter preparing the reagent, add the reagent and sample to the 96-well microplate and react for 30 minutes.


Comparison with a conventional methodWhen measuring antioxidant activity with DPPH, the pH and solvent concentration in the solution affect the measurement. This product uses protocols and analysis methods to minimize these effects.

Effect of pHThe assay buffer provided with the product allows measurement at a certain pH.

Effect of sample solventThe sample volume is set to 1/10 (20 μL) of the total reaction solution. The kit is optimized so that there is no difference in the measured value even if the sample is dissolved in water or ethanol.

IC50 Value VariationIf the antioxidant capacity of a sample is analyzed using only IC50 values, the data will vary slightly in the different measurement conditions. By measuring the sample and standard substance (Trolox) simultaneously and calculating the antioxidant capacity as the Trolox equivalent activity value (TEAC), highly reproducible measurement values can be obtained.TEAC (μg TE/μg) = Trolox IC50 (μg/mL)/ Sample IC50 (μg/mL)”


Measurement ExampleConfirming differences between facilitiesAt three facilities, antioxidants were measured by the DPPH method.Gallic acid, catechin, and morin (known antioxidants) were measured with a spectrophotometer using a cuvette and calculated as a Trolox equivalent activity value (TEAC).There was nearly no difference in measured values between three facilities.Reference: T. Shimamura et al., NipponShokuhin Kagaku Kogaku Kaishi, 2007, 54, 482 – 487.

Comparison between microplate and cuvetteSimilar to the above experiment, three antioxidants were measured using a microplate and calculated as Trolox equivalent activity values. As a result, almost the same measurement results were obtained. This kit uses a microplate for measurement.

IC50 values vary, are there any precautions?
(1) Please make sure that all of the DPPH is dissolved.Please use sonication to dissolve the DPPH Reagent because it is difficult to dissolve.Transfer ethanol to the tube several times as described in the instruction manual. Confirm that the ethanol is no longer colored before use.(2) IC50 values may fluctuate greatly when the sample dilution interval is wide or when measured at the point where the inhibition curve is saturated (see below).Therefore, it is recommended that the optimal concentration range be confirmed in a preliminary experiment.
Can I dissolve DPPH by vortexing or pipetting?
Since DPPH is difficult to dissolve, it cannot be dissolved using vortex and pipetting.Be sure to use an ultrasonic cleaner because undissolved parts may cause variations in IC50.”
How many samples can I measure?
This depends on the kit size:

100 tests500 tests
This kit contains enough reagents to measure one 96-well microplate (1 set of DPPH)Analyzing samples and standards in triplicate is recommended for accuracy.Therefore, the number of measurable samples is calculated as follows, assuming that measurement was performed at n: 3.DPPH Reagent per 1 kit is sufficient for 100 tests.Use for 1 sampleOne sample can be measured with the 100 test size kit.

Number of wells used during preliminary experiment: Confirmation of optimum concentration range

Sample: 8 (dilution series of 8 points) X 3 (n: 3) = 24 wellBlank: 1 (Blank1) X 3 (n: 3) = 3 well

Number of wells used when calculating the IC50 value

Sample: 8 (dilution series of 8 points) X 3 (n: 3) = 24 well

Trolox: 4 (dilution series of 4 points) X 3 (n: 3) = 12 well

Blank: 1 (Blank1) X 3 (n: 3)= 3 well*If there is no require preliminary experiments, the additional sample measurement is possible.

This kit contains enough reagents to measure 5 96-well microplates (5 sets of DPPH)Choose the quantity used based on your experiment (ex. 500 test x1 or 100 test x5)Up to 8 samples8 samples can be measured with the 500 test size kit.Number of wells during the preliminary experiment: Confirmation of optimum concentration rangeSample: 8 (dilution series of 8 points) X 3 (n: 3) X 8 (8 samples) = 192 wellBlank: 1 (Blank1) X 3 (n: 3) X 3 (3 plates) = 9 well

Number of wells when calculating IC50 value

Sample: 8 (dilution series of 8 points) X 3 (n: 3) X 8 (8 samples) = 192 welll

Trolox: 4 (dilution series of 4 points) X 3 (n: 3) X 5 (5 plates) = 60 well

Blank: 1 (Blank1) X 3 (n: 3) X 3 (3 plates) = 9 well

IC50 value is known: 3 samples・If the IC50 value has already been measured with our kit, 3 samples can be measured with one kit.・If the IC50 value is not measured with our kit, it is recommended to perform a preliminary experiment as an unknown sample.

Number of wells when calculating the IC50 valueSample: 8(dilution series of 8 points) X 3 (n: 3) X 3 (Sample number) = 72 wellTrolox: 4 (dilution series of 4 points) X 3 (n: 3) = 12 wellBlank: 1 (Blank1) X 3 (n: 3) = 3 well

If the reaction time until measurement is increase, will the measured value be affected?
Longer reaction times can change the readings.In order to get the good results with reproducibility, measure immediately after incubation (25 ° C, 30 minutes, dark place) as described in the manual.When measuring multiple plates, please unify the measurement time for each plate.
What should I do if my sample is opaque?
If the sample is clear after the pretreatment described in the manual, measurement is possible.

Related Categories Oxidative Stress Assay ACE Inhibition Assay SOD Activity, Glutathione, DNA Damage

品牌介绍
Dojindo细胞分析细胞活力和细胞毒性测定用于药物筛选和化学物质的细胞毒性测试。Dojindo开发了高度水溶性的四唑盐,称为WST。WST-8是高度稳定的WST,用于Cell Counting Kit-8(CCK-8)。由于WST-8甲maz是水溶性的,因此不会形成晶体。因此,不需要诸如MTT测定的增溶过程。此外,CCK-8的检测灵敏度高于其他四唑盐,例如MTT,XTT,MTS或WST-1。WST检测机制 ß-半乳糖苷酶检测试剂细胞增殖/细胞毒性转染细胞染色细胞内荧光探针细菌染色微生物活力测定干细胞分化SPiDER-ßGal线粒体检测细胞代谢应用产品展示细胞生长检测,药物筛选,比色/荧光检测细胞计数试剂盒-8细胞计数试剂盒8 + 96孔有机硅定向剂细胞计数试剂盒-F细胞毒性LDH检测试剂盒-WST 96孔有机硅定向剂MTT了解检测机制的差异:点击这里细胞周期分析细胞周期测定溶液深红色细胞周期测定溶液蓝色